Key features highlights :

RF Performance

  • 14 dBm TX-Power
  • -137 dBm RX-Sensitivity
  • Approx. 10 km range

 Interfaces

  • 2x combined Inputs
  • 0-10V, 0-20mA and PT1000
  • USB (for LoRa Setup)

 ADC Resolution

  • Internal ADC with resolution of 16 Bit used

 Power supply

  • Input voltage +24VDC (10..36VDC)
  • Input current max. 50mA (Typ 6mA @ 24VDC)

 Indicators

  • 4 Status LED’s

 Mechanic

  • Housing: Polyamide (PA 6-GB 30)
  • Dimension (L x B x H) 150mm x 58mm x35mm (incl. antenna)

 Environment

  • Protection class IP65
  • Operating temperature -25°C to +60°C
  • Storage temperature -40°C to 85°C
  • Rel. humidity 0% to 95% (not condensing)

 Reference

  • LoRa® Modbus Bridge technical manual

 Norm & Safety

  • EN 62368-1

Description :

The LPN AI comes with two analog inputs and is ideally suited for a wide range of applications. The idea behind this device is that you can connect any device with an analog output. You can configure the device for two analog Inputs either as 0-10V, 0-20mA or PT1000 input. The data were transmitted or received from any LoRaWAN network, for example in Switzerland trough the public network of Swisscom. Ideally suited for a wide range of applications such as building automation, condition monitoring, predictive maintenance, security, healthcare, smart city and many more.

The compact Size, the outdoor housing and the externally antenna are perfect for outdoor use. The device mounted outdoor gives extra spare if you have bad network coverage. The Input power with 10 to 30 VDC needs to come externally, therefore you don’t have to think about battery lifetime. After the installation, there is an easy procedure with a pushbutton inside the device. So you can check directly if you have coverage or not after the installation of the device.

The status LED’s shows the device status and flashes if a new message is sent or received. Over the LoRaWAN network you can setup the send interval, means you can change the interval every time the device sends an uplink message. A big point is, that the device has inside a USB connection for very easy setup and integration into your LoRaWAN network. Of course, you can use the LoRa AI device with our comtac cloud. There you have the possibilities to send periodically measurement reports or alarm messages. We do also provide cloud our solution with your company logo or we install the software on your server.

The LPN AI comes with two analog inputs which connects 0-10V or 0-20mA or PT1000 sensors to the LoRaWAN network.

Specifications :
Seller comtac AG
SKU 99-1118
Manufacturer Part number LIO-01
Seller SKU LIO-01
Product Attributes Field test
RF Region EU868 - Europe 863-870MHz
LoRa Class Class B
Solution Represented Smart Agriculture, Smart Cities, Energy and Utilities, Health, Smart Industries, Location & Asset Tracking, Transportation, Home, Facilities Management, Other, Smart Operations, Smart Building, Smart Metering, Asset Tracking, Daily Life
RF power (dBm) 14
Battery type Alkaline AA
Output throughput (mW) 20
Antenna External on connector
RF transceiver SX1272
Interfaces Analog
Other interfaces 2 x analog Input
Depth (cm) 6.4
Width (cm) 5.8
Height (cm) 3.4
Certification CE, RoHS
Lead-time if backordered (in working days) 40
Is available for sale Yes
Lead-time if in Stock (in working days) 5
Specific commercial conditions

Default configuration: ABP (OTAA also possible)

Technical documents /_/e/_e1347_technical_datasheet_lpn_ai_en_v0.10.pdf
Seller conditions Seller commercial condition
Seller shipping condition
Share your thoughts for: Comtac AG LPN AI with two analog Inputs AI LIO-01 EU868
Write a customer review

No questions asked yet.

Vendor Questions/Answers:
Ask your question
Only registered users can ask questions. Please Sign in or create an account